Cod
e
Comm.
Addres
s
Name
Setting Range
Initial
Value
Property
*
V/
F
S
L
Ref.
dr-
27
2
0h111B
Auto torque
boost
motoring
gain
0.0300.0[%]
50.0
O
O
X
dr-
28
2
0h111C
Auto torque
boost
regeneratio
n gain
0.0300.0[%]
50.0
O
O
X
dr-80
0h1150
Select
ranges at
power input
Select ranges
inverter displays at
power input
0:
Operatio
n
frequenc
y
O
O
O
-
0
Operation
frequency
1
Acceleration time
2
Deceleration time
3
Command
Source
4
Frequency
reference source
5
Multi-step speed
frequency 1
6
Multi-step speed
frequency 2
7
Multi-step speed
frequency 3
8
Output current
9
Motor RPM
1
0
Inverter DC
voltage
1
1
User select
signal (dr.81)
1
2
Currently out of
order
1
3
Select run
direction
1
4
Output current 2
1
5
Motor RPM 2
1
6
Inverter DC
voltage 2
1
7
User select
signal 2 (dr.81)
dr-81
0h1151
Select
Monitors user
0: Output
O
O
O
-