EasyManuals Logo

LSIS G100 User Manual

LSIS G100
343 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #256 background imageLoading...
Page #256 background image
Cod
e
Comm.
Addres
s
Name
Setting Range
Initial
Value
Property
*
V/
F
S
L
Ref.
dr-12
0h110C
Jog run
acceleration
time
0.0600.0 (s)
20.0
O
O
O
p.114
dr-13
0h110D
Jog run
deceleration
time
0.0600.0 (s)
30.0
O
O
O
p.114
dr-14
0h110E
Motor
capacity
0: 0.2 kW
1: 0.4 kW
2: 0.75 kW
3: 1.1 kW
4: 1.5 kW
5: 2.2 kW
6: 3.0 kW
7: 3.7 kW
8: 4.0 kW
9: 5.5 kW
10: 7.5 kW
11: 11.0 kW
Varies by
Motor
capacity
X
O
O
p.131
dr-15
0h110F
Torque
boost mode
0
Manual
0:
Manual
X
O
X
p.90
1
Auto
dr-16
0h1110
Forward
Torque
boost
0.015.0 (%)
2.0
X
O
X
p.90
dr-17
0h1111
Reverse
torque boost
0.015.0 (%)
2.0
X
O
X
p.90
dr-18
0h1112
Base
frequency
30.00400.00 (Hz)
[V/F, Slip Compen]
40.00120.00 (Hz)
[IM Sensorless]
60.00
X
O
O
p.85
dr-19
0h1113
Start
frequency
0.0110.00 (Hz)
0.50
X
O
O
p.85
dr-20
0h1114
Maximum
frequency
40.00400.00 (Hz)
[V/F, Slip Compen]
40.00120.00 (Hz)
[IM Sensorless]
60.00
X
O
O
p.98
dr-
26
2
0h111 A
Auto torque
boost filter
gain
11000
2
O
O
X
2

Table of Contents

Other manuals for LSIS G100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LSIS G100 and is the answer not in the manual?

LSIS G100 Specifications

General IconGeneral
BrandLSIS
ModelG100
CategoryInverter Drive
LanguageEnglish

Related product manuals