Code
Comm.
Address
Name
Setting Range
Initial
Value
Property*
V/F
SL
Ref.
Pr-30
0h1B1E
Under load
upper limit
level
10100 (%)
30
O
O
O
p.194
Pr-31
0h1B1F
No motor
motion at
detection
0
None
0: None
O
O
O
p.200
1
Free-Run
Pr-32
0h1B20
No motor
detection
current level
1100 (%)
5
O
O
O
p.200
Pr-33
0h1B21
No motor
detection
time
0.110.0 (s)
3.0
O
O
O
p.200
Pr-40
0h1B28
Electronic
thermal fault
selection
0
None
0: None
O
O
O
p.177
1
Free-Run
2
Dec
Pr-41
0h1B29
Motor cooling
fan type
0
Self-cool
0: Self-
cool
O
O
O
p.177
1
Forced-cool
Pr-42
0h1B2A
Electronic
thermal 1
minute rating
120200 (%)
150
O
O
O
p.177
Pr-43
0h1B2B
Electronic
thermal
continuous
rating
50150 (%)
120
O
O
O
p.177
Pr-45
0h1B2D
BX trip mode
0
Free-Run
0
X
O
O
-
1
Dec
Pr-50
0h1B32
Stall
prevention
motion and
flux braking
bit
00001111
0000
X
O
X
p.181
0001
Accelerating
0010
At constant
speed
0100
Decelerating
1000
FluxBraking
Pr-51
0h1B33
Stall
frequency 1
Start frequency
Stall frequency2
(Hz)
60.00
O
O
X
p.181
Pr-52
0h1B34
Stall level 1
30250 (%)
180
X
O
X
p.181
Pr-53
0h1B35
Stall
frequency 2
Start frequency1
Stall frequency3
(Hz)
60.00
O
O
X
p.181
Pr-54
0h1B36
Stall level 2
30250 (%)
180
X
O
X
p.181

Table of Contents