Code
Comm.
Address
Name
Setting
Range
Initial Value
Prop
erty*
V/
F
S
L
Ref.
M2-31
0h1C1F
Low-speed
torque
compensation
gain
50300 (%)
Varies by
Motor
capacity
X
X
O
p 137
M2-32
0h1C20
Stator leakage
inductance
scale
50300 (%)
Varies by
Motor
capacity
X
X
O
p 137
M2-33
0h1C21
Stator
inductance
scale
50300 (%)
Varies by
Motor
capacity
X
X
O
p 137
M2-34
0h1C12
Rotor time
constant scale
50300 (%)
Varies by
Motor
capacity
X
X
O
p 137
M2-40
0h1C28
Rotation count
speed gain
0.1
6000.0[%]
100.0
O
O
O
-
M2-41
0h1C29
Rotation count
speed scale
0
x 1
0: x 1
O
O
O
-
1
x 0.1
2
x 0.01
3
x 0.001
4
x 0.0001
M2-42
0h1C2A
Rotation count
speed unit
0
Rpm
0: rpm
O
O
O
-
1
mpm