EasyManuals Logo

LSIS G100 User Manual

LSIS G100
343 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #294 background imageLoading...
Page #294 background image
Code
Comm.
Address
Name
Setting
Range
Initial Value
Prop
erty*
V/
F
S
L
Ref.
M2-31
0h1C1F
Low-speed
torque
compensation
gain
50300 (%)
Varies by
Motor
capacity
X
X
O
p 137
M2-32
0h1C20
Stator leakage
inductance
scale
50300 (%)
Varies by
Motor
capacity
X
X
O
p 137
M2-33
0h1C21
Stator
inductance
scale
50300 (%)
Varies by
Motor
capacity
X
X
O
p 137
M2-34
0h1C12
Rotor time
constant scale
50300 (%)
Varies by
Motor
capacity
X
X
O
p 137
M2-40
0h1C28
Rotation count
speed gain
0.1
6000.0[%]
100.0
O
O
O
-
M2-41
0h1C29
Rotation count
speed scale
0
x 1
0: x 1
O
O
O
-
1
x 0.1
2
x 0.01
3
x 0.001
4
x 0.0001
M2-42
0h1C2A
Rotation count
speed unit
0
Rpm
0: rpm
O
O
O
-
1
mpm

Table of Contents

Other manuals for LSIS G100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LSIS G100 and is the answer not in the manual?

LSIS G100 Specifications

General IconGeneral
BrandLSIS
ModelG100
CategoryInverter Drive
LanguageEnglish

Related product manuals