11.2 Product Specification Details
Items
Description
Control
Control method
V/F control, slip compensation, sensorless vector
Frequency
settings power
resolution
Digital command: 0.01 Hz
Analog command: 0.06 Hz (60 Hz standard)
Frequency
accuracy
1% of maximum output frequency
V/F pattern
Linear, square reduction, user V/F
Overload
capacity
Heavy load rated current: 150%, 1 minute,
Light load rated current: 120%, 1minute
Torque boost
Manual torque boost, automatic torque boost
Operation
Operation type
Select key pad, terminal strip, or communication
operation
Frequency setting
Analog type: -1010 V, 010 V, 420 mA
Digital type: key pad
Operation
function
PID Control
3-Wire Operation
Frequency limit
Second motor function
Anti-forward and reverse
direction rotation
Commercial transition
Speed search
Power braking
Up-down operation
DC braking
Frequency jump
Slip compensation
Automatic restart
Auto tuning
Energy buffering
Flux braking
Fire Mode
Input
Multi-
function
terminal
(5EA)
P1P5
Select PNP (Source) or NPN (Sink) mode.
Functions can be set according to In.65 In.69 codes
and parameter settings.
Forward direction
operation
Reset
Emergency stop
Multi step speed
frequency-high/med/low
DC braking during stop
Frequency increase
3-wire
Select acc/dec/stop
Reverse run
External trip
Jog operation
Multi step acc/dec-
high/med/low
Second motor selection
Frequency reduction
Fix analog command
frequency
Transition from PID to
general operation

Table of Contents