11.8 Continuous Rated Current Derating
Carrier Frequency
The continuous rated current of the inverter is limited based on the carrier frequency.
Refer to the following graph.
Carrier
frequency
(kHz)
Continuous rated current
0.4~2.2kW
4.0kW
5.5kW
7.5kW
200V
400V
200V
400V
200V
400V
200V
400V
1~4
100%
100%
100%
100%
100%
100%
100%
100%
6
100%
100%
93%
100%
93%
93%
91%
89%
9
91%
91%
83%
85%
83%
83%
79%
72%
12
81%
81%
73%
70%
73%
73%
69%
59%
15
72%
72%
62%
58%
62%
62%
58%
48%

Table of Contents