Manitowoc Published 05-09-17, Control # 014-28 3-13
16000 SERVICE/MAINTENANCE MANUAL ELECTRIC SYSTEM
3
34-R DO-15 Pump 3 Control (Drum 4/Drum 5)
See
Table 3-2, page 3-8
CAN25-2-64
34-S DO-18 Pump 6 Control (Drum 2/Drum 1)
See
Table 3-2, page 3-8
CAN25-3-2
34-T Ground Pump 2 Control (Left Travel/Drum 3) Ground
34-U DO-19 Pump 2 Control (Left Travel/Drum 3)
See Table 3-2, page 3-8
CAN25-3-4
34-V Ground Pump 2 Control (Left Travel/Drum 3) Ground
34-W DO-20 Pump 2 Control (Left Travel/Drum 3)
See
Table 3-2, page 3-8
CAN25-3-8
34-X Ground Pump 1 Control (Right Travel/Drum 4) Ground
34-Z DO-21 Pump 1 Control (Right Travel/Drum 4)
See
Table 3-2, page 3-8
CAN25-3-16
34-a Ground Pump 1 Control (Right Travel/Drum 4) Ground
34-b DO-22 Pump 1 Control (Right Travel/Drum 4)
See Table 3-2, page 3-8
CAN25-3-32
34-c Ground Pump 5 Control (Swing) Ground
34-d DO-23 Pump 5 Control (Swing)
See
Table 3-2, page 3-8
CAN25-3-64
34-e Ground Pump 5 Control (Swing) Ground
34-f DO-24 Pump 5 Control (Swing)
See
Table 3-2, page 3-8
CAN25-3-128
34-g Ground Jumper to Node Select 2 Ground
34-j NS-2 Node Select Jumper to Ground 0 Volts (With Jumper)
W36 Receptacle — Angle Sensors, Alarm and Drum Pawl
36-A Ground Left Side RCL Capacity Alarm Ground
36-B DO-7 Left Side RCL Capacity Alarm 0 Volts Off; 24 Volts On CAN25-1-64
36-C Ground Drum 2 Left Side Motor Control (Optional) Ground
36-D DO-8 Drum 2 Left Side Motor Control (Optional)
See
Table 3-2, page 3-8
CAN25-1-128
36-E Ground Boom/Mast Hoist (Drum 4) Pawl Sol. - Out Ground
36-F DO-9 Boom/Mast Hoist (Drum 4) Pawl Sol. - Out 0 Volts Off; 24 Volts On CAN25-2-1
36-G Ground Boom/Mast Hoist (Drum 4) Pawl Solenoid - In Ground
36-H DO-10 Boom/Mast Hoist (Drum 4) Pawl Solenoid - In 0 Volts Off; 24 Volts On CAN25-2-2
36-J DI-8 Hydraulic Return Filter Alarm Switch (Bottom) 0 Volts Off; 24 Volts On CAN45-1-128
36-L NS-2 Node Select 2 Jumper to Ground 0 Volts (With Jumper)
36-P DI-7 Hydraulic Charge Filter Alarm Switch 0 Volts Off; 24 Volts On CAN45 -1-64
36-R 24 Volts Hydraulic Charge Filter Alarm Switch 24 Volts Nominal
36-U Ground Jumper to Node Select 2 Ground
36-V 5 Volts Mast Angle Sensor 5 Volts
36-W Ground Mast Angle Sensor Ground
36-X 24 Volts Hydraulic Return Filter Alarm Switch (Bottom) 24 Volts Nominal
36-Z Ground MAX-ER Mast Strap Load Pin Ground
36-d AI-12 Mast Angle Sensor 5 volts DC Mast at Vertical CAN6-8 *1
36-j Ground MAX-ER Mast Strap Load Pin Ground
36-k AI-16 MAX-ER Mast Strap Load Pin 24 Volts Nominal CAN7-8 *1
36-m 24 Volts MAX-ER Mast Strap Load Pin 24 Volts Nominal
*1 – Lower four bits can be multiplied by 5 or 10 depending on sender, then divided by 16 for an estimation of sender
voltage.
*2 – Number in indicated bank should increment in positive direction and decrement in negative direction with item rotation.