HYDRAULIC SYSTEM 16000 SERVICE/MAINTENANCE MANUAL
2-34
Published 05-09-17, Control # 014-28
Pump or Motor Override
See Figure 2-34 for the following procedure.
1. Start and run engine at low idle.
2. Rotate manual override (2) in either direction to stroke
pump or motor in corresponding direction.
3. If pump or motor is operating properly, corresponding
side of circuit will stall.
Solenoid Valve Override
See Figure 2-34 for the following procedure.
1. Start and run engine at low idle.
2. Insert a rigid steel rod through hole in end of valve cap.
3. Depress valve spool with rod.
4. If valve is operating properly, corresponding side of
circuit should operate.
Item Description
1 Pump or Motor EDC
2 Manual Override
3 Electric Connector
4 Solenoid Valve
5 Manual Override (though end cap)
FIGURE 2-34
1
P966a
3
Typical Pump or Motor Installation
2
Typical Solenoid Valve Installation
P2308a
4
3
5