16000 SERVICE/MAINTENANCE MANUAL ELECTRIC SYSTEM
3
Boom or Swing Motion Limiter Mode
See Figure 3-30 in the following procedure.
NOTE: Motion limiter mode data boxes do not appear
unless crane has this option.
In level 3, use the Select buttons to enable or disable the
motion limiter mode. When in level 3 with the motion limiter
mode enabled, the controller monitors and stores the
maximum right/left or up/down angles during operation. After
exiting level 3, these angles are used to limit boom or swing
motion.
Crane Setup Remote Mode
To turn on the crane setup remote control, see the procedure
in Section 3 of the Crane Operator Manual.
Fan Function
See Figure 3-33 for the following procedure.
The fan speed can be set above a minimum 25% of rated
speed in increments of 5% (to 30%, 35%, 40%, etc.). The
minimum fan speed is set by the factory and does not
require further adjustment.
CAN Bus Screen
See Figure 3-34 for the following procedure.
The CAN (Controller Area Network) bus diagnostic screen is
for technicians. The screen displays CAN bus packet and
node information, engine status, history status, and boom
status. Any node that is yellow indicates that communication
is lost to that node.
The CAN Bus screen operates on two levels:
Level 1 — Packet number data box highlighted blue
Level 2 — Packet number data box highlighted red
Packet Information
See Figure 3-34, items 1 to 5.
The top row of the screen contains CAN Bus packet number
(26). Enter the desired packet number in the first data box by
using Select buttons.
Packet type (DO) is displayed on top middle data box.
Related node (2) is displayed in top last data box.
Packet contents are displayed in the eight banks under the
row. Packet content and format depends on packet type.
Many packets are not easily interpreted by other than factory
technical personnel and their content is not discussed in this
publication.
FIGURE 3-31
D16-22
FIGURE 3-32
Luffing Jib
Setup Screen
I = ON
O = OFF
Remote
Control
Screen
Past Production
Current Production
TxID Number
Remote
Control
Screen
FIGURE 3-33
14COM3-30
D16-25C
FIGURE 3-34
Item Description Item Description
1 Packet Number 7 Drum Load Links
2 Packet Type 8 Remote Status
3 Packet Node Number 9 Boom Node Status
4 Packet Banks (8) 10 Wireless Receiver Status
5 Bank 1 Total 11 Crane Status
6 Engine Node Status 12 Crane History
5
12
10
9
4
6
8
1
2
3
7
11

Table of Contents

Other manuals for Manitowoc 16000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc 16000 and is the answer not in the manual?

Manitowoc 16000 Specifications

General IconGeneral
BrandManitowoc
Model16000
CategoryConstruction Equipment
LanguageEnglish

Related product manuals