Manitowoc Published 05-09-17, Control # 014-28 7-7
16000 SERVICE/MAINTENANCE MANUAL POWER TRAIN
Service
Service the air cleaner and its primary and secondary filter
elements per the intervals specified by the engine
manufacturer and per the engine manufacturerās
instructions. An illustration of these instructions is located on
the air filter cover (see Figure 7-4
).
Replacement of the primary filter is indicated only when the
red flag locks in place at the top of the service indicator.
NOTE: The recommended service interval for replacing
the secondary element is every 3rd time the
primary element is replaced
1. Wipe any accumulated dirt, grease, or other foreign
material from the outside surface of the air cleaner
assembly to prevent contamination when opening the air
cleaner or integral pre-cleaner assemblies.
Do not allow foreign matter to enter housing, tubing
or air inlet hole to the engine.
2. Refer to the engine manufacturerās instructions to open,
service and close the air cleaner or integral pre-cleaner
assemblies.
CAUTION
Engine Damage!
STOP ENGINE before servicing air cleaner, or unfiltered
air will be drawn directly into engine.
Do not attempt to clean and reuse old filter. Discard old
filter and install a new one.