16000 SERVICE/MAINTENANCE MANUAL TROUBLESHOOTING
10
PROBLEM 24
Accessory pin cylinder(s) will not extend or retract.
CHECKS
Does system pressurize to 3,000 psi (207 bar) when moving problem switch to extend or
retract position at hand-held wireless remote?
POSSIBLE CAUSES
Faulty control valve section; Low pump pressure; Bad pump; Switch failure;
Mechanical problem.
Yes No
Are mechanical problems present at
pin cylinders?
Yes No
When moving problem switch, does accessory system pressure
increase?
Voltage
No Voltage
Yes No
Check hand-held wireless
remote operation.
Check for 28 volts at problem pin switch.
Replace cylinder.
Repair
problem.
Are solenoids magnetized when switch position is enabled?
Yes No
Replace power switch.
Replace solenoid valve/wiring.
Check system pressure for 3,000 psi (207 bar).
Pressure Ok Pressure not Ok
Repair or replace
control valve.
Check accessory/MAX-ER pump pressure output.
Repair or replace pump, if necessary.

Table of Contents

Other manuals for Manitowoc 16000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc 16000 and is the answer not in the manual?

Manitowoc 16000 Specifications

General IconGeneral
BrandManitowoc
Model16000
CategoryConstruction Equipment
LanguageEnglish

Related product manuals