Malfunctions in driving mode
7.3 Towing the truck crane
7 - 10 3 112 xxx en Operating Manual GMK6300L
xx.xx.xxxx
7.3.3 External starting socket
The truck crane is equipped with a socket for external starting (1) on the
carrier and on the superstructure (
à p. 14 - 79).
If the batteries are discharged, the power supply (24 V) of an auxiliary vehi-
cle or the socket (1) on the superstructure can be used for charging.
Start the engine of the power source (24 V).
(A) – Connect the cable (1) to the power
supply.
Insert the plug (2) into the socket (3).
Start the engine for driving.
(B) – Withdraw the plug (2).
Close the socket (3).
Remove the cable (1) from the power
supply.
Performing a jump
start
The socket (1) can also be used to supply power to another vehicle
(with a 24 V on-board network).
Start the engine for driving.
(A) – Insert the plug (2) into the socket (3) on
the carrier.
Connect the cable (1) to the vehicle requiring
the power (24 V).
Start the engine of the vehicle that requires
the power.
(B) – Withdraw the plug (2).
Close the socket (3).
Remove the cable (1) from the vehicle.