Malfunctions in driving mode
7.6 Troubleshooting
Operating Manual GMK6300L 3 112 xxx en 7 - 27
xx.xx.xxxx
7.6 Troubleshooting
This section does not include all malfunctions.
If a warning is shown in the display (1);
à p. 5 - 48.
If the lamp on the instrument panel (2)
lights up;
à p. 5 - 51.
7.6.1 Malfunctions on the engine
H
In addition to this information; à Separate engine operating instructions,
provided by the manufacturer
.
.
Malfunction Cause Remedy
Engine does not start
Starter does not turn
Battery master switch is
switched off
Switch on the battery master
switch;
à p. 4 - 10
Switch the ignition off
à Switch on the ignition,
p. 4 - 11
Transmission not in neutral
position
à Switching the transmission to
the neutral position
, p. 5 - 28
Parking brake released Lock the parking brake;
à p. 3 - 55
Fuse F1/5 blown Replace blown fuses;
à p. 7 - 20
Bridging plug for the hand-held
control not inserted
Insert bridging plug;
à p. 12 - 21
Emergency stop switch
pressed
Release the emergency stop
switch;
à p. 4 - 24
s