Malfunctions during crane operation
14.6 Hydraulic emergency operation
14 - 66 3 112 xxx en Operating Manual GMK6300L
xx.xx.xxxx
Emergency supply
When using an emergency supply, the con-
nections (1) feed a transformer (2) that is con-
nected to the hydraulic system of the other
crane;
à Emergency supply of another crane,
p. 14 - 76.
14.6.2 Connecting/disconnecting hoses
Turn off the engines for driving and crane operations.
Establishing
connections
The hoses are assigned according to the various diameters.
On the carrier
Attach the transformer (3) to the super-
structure.
Connect the hoses (2) to the connections (1).
S
Risk of damage to the hoses!
Lay the hoses in such a manner that they can be moved freely, so as to pre-
vent them being crushed or torn or becoming caught during subsequent
crane movements.