Operating elements for crane operation
9.2 Short description of the operating elements
Operating Manual GMK6300L 3 112 xxx en 9 - 59
xx.xx.xxxx
9.2.3 Engine for crane operation
Side panel à Starting the engine, p. 10 - 12.
Ignition lock
Carrier ignition monitoring
Set idling speed
The engine must be off:
The engine is running
:
Flame start system monitoring
s
–0 Ignition off, engine off, key can be removed
–R, 1 Ignition on and power supply on for:
Instrument lighting, ECOS, engine control system, RCL
–2 Starting position
à p. 10 - 9
–On: Ignition in driver's cab on,
engine start not possible
Off: Ignition in driver's cab off,
engine start possible
à p. 10 - 12
Press down once: Engine starts,
Idling speed = standard
Press down: Increasing the idling speed
Press up: Decrease idling speed,
after about 6 seconds: engine stop.
à p. 10 - 16
–On: Engine not ready to start – is being warmed up
Off: Engine is ready to start
à p. 10 - 13