Crane operation
11.2 Operation of the rated capacity limiter
11 - 46 3 112 xxx en Operating Manual GMK6300L
xx.xx.xxxx
Cancelling the override
The override will be cancelled when you:
Switch off the ignition
Press the key-operated switch again.
The override will automatically be cancelled 30 minutes after the key-oper-
ated switch has been pressed.
Table – error/
information codes
The following table contains error and information codes, their causes and
possible solutions.
S
Risk of accidents due to unintentional override!
The key must not remain in the key-operated switch while the crane is
operating!
This prevents the RCL from overriding unintentionally.
Error code Cause Remedy
804 4 Key-operated rigging
switch pressed, no override
effective
Start the engine;
Reduce degree of utilisation to less
than 110%
Move the control lever within
10 seconds after operation
805 4 Raise switch pressed, no
override effective
Start the engine;
Press switch again
806 4 Key-operated RCL override
switch pressed, no override
effective
Start the engine;
Press switch again
8 04 5 Information code:
Key-operated rigging
switch pressed, override
effective
No measures required.
8 05 5 Information code:
Raise switch pressed,
override effective
8 06 5 Information code:
Override RCL switch
pressed, override effective