Malfunctions during crane operation
14.5 Emergency operations and programs
14 - 44 3 112 xxx en Operating Manual GMK6300L
xx.xx.xxxx
Releasing the lock
• (A) – Telescope out approx. 35 mm (0.11 ft),
so that the cutout (4) is accessible.
• (B) – Screw a bolt into the bore (1). The lock-
ing pins (2) must retract behind the tele-
scopic section (3).
If necessary, give the locking pin (2) a slight
knock to help this procedure.
• Unlock the other side of the telescopic
section as well.
Locking the telescopic section
• (A) – Retract the telescoping until the locking
pin (2) is in the middle of the opening.
• Screw the screw out of the bore (1) until the
locking pin is fully extended.
• Remove the bolt from the bore hole.
• (B) – Retract the telescoping further until the
telescopic section is set down.
S
Risk of damage due to a mechanically released lock!
Under no circumstances may you operate the telescoping cylinder whilst
the lock is mechanically released. Unscrew all bolts out of the bores imme-
diately after finishing the repair work.
This prevents damage to the telescoping cylinder and the locking system.

Table of Contents

Other manuals for Manitowoc Grove GMK6300L-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK6300L-1 and is the answer not in the manual?

Manitowoc Grove GMK6300L-1 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK6300L-1
CategoryConstruction Equipment
LanguageEnglish

Related product manuals