Malfunctions during crane operation
14.5 Emergency operations and programs
Operating Manual GMK6300L 3 112 xxx en 14 - 55
xx.xx.xxxx
Tables for
approaching the
locking points
The extent to which the telescoping cylinder has to be extended in order to
reach a locking point depends on whether you want to lock:
– the telescoping cylinder or
– a telescopic section.
Locking points for the telescoping cylinder
The following table shows the extended length for locking the telescoping
cylinder.
Locking points for the telescopic sections
s
Table for locking the telescoping cylinder
Telescopic
section
Locking point at
fixed length
Extended length of
telescoping cylinder
in% in mm (in ft)
Telescopic
section
I
0
50
100
5
5,350
10,898
(0.02)
(17.55)
(35.76)
Telescopic
section
II
0
50
100
447
5,752
11,290
(1.47)
(18.87)
(37.04)
Telescopic
section
III
0
50
100
846
6,124
11,568
(2.78)
(20.09)
(37.95)
Telescopic
section
IV
0
50
100
1,155
6,445
11,911
(3.79)
(21.15)
(39.08)
Telescopic
section
V
0
50
100
1,440
6,717
12,168
(4.72)
(22.04)
(39.92)
Telescopic
section
VI
0
50
100
1,712
6,941
12,168
(5.61)
(22.77)
(39.92)