Maintenance overview
5.2 Maintenance plans
16.08.2018
Maintenance manual 3 302 577 en 5 - 17
GMK7450
5.2.8 Maintenance plan Y 3
5.2.9 Maintenance plan Y 5
Maintenance work on the CARRIER:
every 36 months
Engine
–Notes;
à Engine manufacturer’s documentation à P. 7 - 11
Maintenance work on the SUPERSTRUCTURE:
every 36 months/after 3,000 oper. hrs.
Engine
–Notes;
à Engine manufacturer’s documentation à P. 8 - 13
Hoists
– Having a partial inspection carried out
à P. 8 - 48
Maintenance work on the CARRIER:
every 60 months / 100, 000 km (62 000 mi)
Engine
–Notes;
à Engine manufacturer’s documentation à P. 7 - 11
– Have the Cardan shaft between the transmission on the engine and the trans-
fer case replaced by
Manitowoc Crane Care or an authorised GROVE dealer.
Maintenance work on the SUPERSTRUCTURE:
every 60 months/after 5,000 oper. hrs.
Engine
–Notes;
à Engine manufacturer’s documentation à P. 8 - 13