– 3.32 –
Mark jagged
When the mark is jagged, the mark origin will be detected incorrectly, and that may lead to cutting
distortion.
*To make the distance between registration marks equal to the cutting length,
input the distance between printed marks found by the mark detecting
function. In this case, scale correction between the registration marks is prior
to distance correction in the function.
If changes the distance correction value, the scale correction between the
registration marks will be invalid.
* Clear the origin position, sheet slope correction, and the scale correction of
the registration marks by turning over the clamp lever toward you.
* Once the device detects marks, the origin will be established at the location
of TP1. If you establish another origin at a different location using the jog
key (arrow key), the origin will be rendered effective.
* The rotating function is rendered ineffective.