Maintaining Capping station
5-15
1
2
3
4
5
Routine Maintenance
6
Press the key to fill the cap with the
cleaning solution.
• The cleaning solution is applied by drops when the
is pressed.
• When the is pressed again, drops stop.
• Repeat the drops several times to fill the cap with the cleaning
solution just before the solution overflows from the cap.
7
Close the front cover and press the key.
8
Set the duration for leaving the cleaning solution by
pressing the keys.
Set value : 1 to 99 minutes (Unit: minute)
9
Press the key.
• Perform the nozzle cleaning.
• On completion of the nozzle cleaning, the head moves to above the
platen.
10
Open the front cover.
11
Press the key to fill the cap with the cleaning solution.
• The cleaning solution is applied to the cap by drops when the is pressed.
• When the is pressed again, drops stop.
• During the idle absorbing is interrupted, repeat the drops several times to fill the cap with the cleaning
solution just before the solution overflows from the cap.
12
Close the front cover and press the key.
• It returns to the local mode after the initial operation.
ST . MA I NTENANCE
LEAV I NG T IME :
1mi n
ST . MA I NTENANCE
LEAV I NG T IME :
2mi n
*Be i ng I n i t i a l i zed*
PLEASE WA I T
*Be i ng I n i t i a l i zed*
PLEASE WA I T
<LOCAL . 1>