Setting Pump tube washing interval in Standby mode
Perform the pump tube washing periodically to prevent ink from clogging due to the coagulation of ink, which
occurs within the tube.
1
Select [ROUTINE SETUP] of the maintenance menu.
(1) Press the key in the local mode.
(2) Select [MAINTENANCE] by pressing the keys then press the key.
(3) Select [ROUTINE SETUP] by pressing the keys.
(4) Press the key.
2
Select [PUMP TUBE WASH] by pressing the
keys.
3
Press the key.
4
Set the tube washing interval by pressing the
keys.
• Set value : OFF, 1 - 168 hours
5
Press the key.
6
Press the key several times to end.
• This function is operable only under the condition that the machine is left in the following displays.
• When the cleaning solution has not been filled in the machine, the
right display is displayed at the step 5. Fill the cleaning solution
( P.5-8) then redo the operations from the step 1.
<LOCAL . 1> [ #01 ] *REMOTE. 1* [ #01 ]
0.00m
LOCAL mode REMOTE mode
ROUT I NE SETUP
PUMP TUBE WASH < e n t >
ROUT I NE SETUP
WA S H I N T E R V A L =
1 h
ROUT I NE SETUP
WA S H I N T E R V A L =
4 h
ROUT I NE SETUP
PUMP TUBE WASH < e n t >