5-25
Preventing nozzle clogging while power-off
1
2
3
4
5
Routine Maintenance
Setting tube washing interval in Sleep mode
Set the interval at which cleaning of the caps and pump tubes is to be performed using the cleaning solution
during sleep mode.
1
Select [SLEEP SETUP] of the maintenance menu.
(1) Press the key in the local mode.
(2) Select [MAINTENANCE] by pressing the keys then press the key.
(3) Select [SLEEP SETUP] by pressing the keys.
(4) Press the key.
2
Select [PUMP TUBE WASH] by pressing the
keys.
3
Press the key.
4
Set the tube washing interval by pressing the
keys.
Set value : OFF, 1 - 168 hours
5
Press the key.
6
Press the key several times to end.
When the cleaning solution has not been filled in the machine, the
right display is displayed at the step 5. Fill the cleaning solution
( P.5-8) then redo the operations from the step 1.
SLEEP SETUP
PUMP TUBE WASH < e n t >
SLEEP SETUP
WA S H I N T E R V A L =
1 h
SLEEP SETUP
WA S H I N T E R V A L =
4 h
SLEEP SETUP
PUMP TUBE WASH < e n t >
** Washing Liquid **