3-34
Change the operation condition of the ambient temperature
If you print in the status that the temperature of the place in which the machine has installed (ambient
temperature) is out of the usable temperature range, ink discharging defect or changing color may occur, and it
adversely affects the printing quality.
Here, select the operation if the ambient temperature is out of the usable temperature range when printing.
1
Press the key in the local mode.
2
Select [MACHINE SETUP] by pressing the keys.
3
Press the key.
4
Select [ENV.TEMP.] by pressing the keys.
5
Press the key.
6
Press to select a set value.
Not wait ARR. : The error message is displayed for a moment, and printing starts.
Wait arrival : After the error message is displayed, wait until the ambient temperature reaches the
proper value. Then, printing starts.
7
Press the key.
8
Press the key several times to end.
• For the details of the usable temperature range, refer to P.7-3 “Available temp.”.
• If the ambient temperature is out of the usable temperature range at the start of printing, the error
message below is displayed to inform you of it.
**** ERROR 120 ****
ENV I RONMENT TEMP ( LO )
**** ERROR 121 ****
ENV I RONMENT TEMP ( H I )
FUNCT I ON
MACH I NE S E TUP < ENT >
MACH I NE S E TUP
DEODOR I Z E F AN < e n t >
MACH I NE S E TUP
ENV . TEMP . < e n t >
ENV . TEMP .
SEL :
N ot wai t ARR.