Preventing nozzle clogging while power-off
5-26
Setting cleaning interval in Sleep mode
This function is to be executed instead of TUBE WASH after the cleaning solution has been used up.
Set the cleaning type and the interval at which cleaning operation is to be performed during sleep mode.
1
Select [SLEEP SETUP] of the maintenance menu.
(1) Press the key in the local mode.
(2) Select [MAINTENANCE] by pressing the keys then press the key.
(3) Select [SLEEP SETUP] by pressing the keys.
(4) Press the key.
2
Select [CLEANING] by pressing the keys.
3
Press the key.
4
Set the cleaning interval by pressing the keys.
• Set value : OFF, 1 - 168 hours
5
Press the key.
• The selection display of the cleaning type is displayed.
6
Select the cleaning type by pressing the keys.
• Set value : NORMAL, SOFT, HARD
7
Press the key.
8
Press the key several times to end.
SLEEP SETUP
CLEAN I NG <en t >
SLEEP SETUP
CLEAN . INTERVAL =
1 h
SLEEP SETUP
CLEAN . INTERVAL =
4 h
SLEEP SETUP
CLEAN . TYPE :
NORMA L
SLEEP SETUP
CLEAN . TYPE :
SOFT
SLEEP SETUP
CLEAN . INTERVAL =
4 h