6-11
Warning / Error Messages
1
2
3
4
5
6
Troubleshooting
Message Cause Solution
Any parameter outside the range of
acceptable numeric values was
received.
Turn off the main power to the machine
and turn it on after a while.
If the same error message appears
again, contact your local distributor to
call for service.
The received data does not follow the
command system set by the machine.
Transmit data that is compatible with
the command system supported by this
machine.
An error occurred in communication
between the host computer and the
interface board for USB2.0
connection.(Full-Speed mode
connection)
Check that the host PC supports the
USB2.0 interface.
(Communication can be resumed
without changing any setting. However,
it is recommend to use the connection
in High-Speed mode.)
An error occurred in communication
between the host computer and the
interface board for USB2.0 connection.
Check that the cable is securely
connected to the host computer and
interface board.
Also, check to see if any error has
occurred on the host computer.
An error occurred in communication
between the host computer and the
interface board for USB2.0 connection.
An error occurred in communication
between the host computer and the
interface board for USB2.0 connection.
An error occurred in communication
between the host computer and the
machine for USB2.0 connection.
Improper operation was conducted on
the operation panel.
Perform correct operations.
It is being tried to change settings for
functions though there remains
received data that has not yet been
printed.
Print all the received data or execute
the data clear function. Then, change
settings.
An excessive load was applied to the X
motor.
Turn off the main power to the machine
and turn it on after a while.
If the same error message appears
again, contact your local distributor to
call for service.
An excessive load was applied to the Y
motor.
An error due to an excessive current of
the X motor was detected.
An error due to an excessive current of
the Y motor was detected.
An error occurred in the capping
control. (Improper parameter
adjustment value)
***** ERROR 11 *****
PARAMETER ERROR
***** ERROR 16 *****
MR L COMMAND
***** ERROR 25 *****
FULL - SPEED
***** ERROR 25 *****
PACKET S I ZE OVER
***** ERROR 25 *****
USB PROTOCOL
***** ERROR 25 *****
USB ENV I RONMENT
***** ERROR 25 *****
USB DATA
***** ERROR 30 *****
OPERAT I ON ERROR
***** ERROR 34 *****
DATA REMA I N
***** ERROR 40 *****
MOT OR A L A RM X
***** ERROR 41 *****
MOT OR A L A RM Y
***** ERROR 42 *****
X OVER CURRENT
***** ERROR 43 *****
Y OVER CURRENT
***** ERROR 45 *****
CAPP I NG : PARAMETER