EasyManua.ls Logo

MIMAKI TS100-1600 - Page 102

MIMAKI TS100-1600
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 Replacement of Maintenance Parts > Miscellaneous>Wiper unit
102
7. Remove the Wiper unit. (Screws ×2)
8. Follow the procedure in the reverse order for assembly.
Check the position of the wiper cleaner BKT. If the position is different from the illustration
below, reattach it to the correct position.
Cut approximately 5 mm off the end of the tube to be connected to the wiper tray before
reinserting.
Improper attachment may result in leaking ink.
Cut the tip of the discharge tube diagonally (about 10 mm) and insert into the ST tray outlet to a
length of about 20 mm.
Check to confirm the tube does not protrude from the ST tray.
9. Perform "3.1.5 Wiper Height Adjustment"(P. 116).