l Overview
At the same time as the test print, various information (for R&D checking) is printed.
$%&'
+HDG
$%
&
'
+HDG
8-9(*Y\\PPGGKKPP
/861/



$%&'
+HDG
$%
&
'
+HDG
8-9(*Y\\PPGGKKPP
/861/



[IC information]
*Printed in maintenance mode
*The details are not available.
Serial No.
Ink Type
Model name
Firmware version Print date
Service code
1 2 3 4 5 6 7 8 9 10 11
[Service code]
l Service codes
No. Item Outline
1 Ink set code Reference: "1.3 Major Parameters"(P. 18)
2 Cleaning progress [Initial] cleaning type
I: Not performed
N: Normal cleaning
S: Soft cleaning
H: Hard cleaning
[Digit] Head cleaned (bit assignment)
Head 1_ABCD = 1 (bit 0)
Head 2_ABCD = 4 (bit 3)
Example)
Head 1 only: 1 = 1
Head 2 only: 4 = 4
All heads: 1 + 4 = 15
3 Time elapsed since last cleaning The time elapsed since the last cleaning is indicated by three
digits. Times of under one hour are indicated by “_”
(underscore) for the first digit to differentiate from times of one
hour or longer.
Example:
7 mins = _07
30 mins = _30
1 hour 30 minutes = 015
20 hours = 200
4 Head gap L: Low gap, H: High gap
5 Ambient temperature Keyboard PCB thermistor temperature
Indicates temperature 2 °C to 3 °C above actual room
temperature. (Same applies for 6 and 7.)
6 Ambient temperature - high Maximum ambient temperature reached during printing
7 Ambient temperature - low Minimum ambient temperature reached during printing
8 Maintenance liquid status 0: Normal, 1: End, 2: None
9 Ink capacity 0: 1,000 ml
10 Nozzle recovery registration 0: Not registered, 1: Registered