Chapter 2 Replacement of Maintenance Parts > Ink Supply Related>Bottle tank
89
>
R
e
v
2.4.7 Bottle tank
[Front Side] [Rear Side]
3
1
2
4
l Procedure
1. Drain the ink.
Reference: "3.2.5 Discharge and Washing"(P. 138)
2. Turn off the main power supply and unplug the power cable.
3. Remove the following covers.(1.5)
(1) Bottle top cover
(2) Bottle back cover upper
(3) Bottle cover L
(4) Bottle cover R
4. Remove the Bottle tank together with the tank BKT.
Be careful to avoid bending the ink tubes.
5. Remove the Fluid level detection sensor.
6. Disconnect the tube connected to the Bottle tank.
Be careful to avoid contaminating the surrounding area with ink.
Be careful to avoid bending the ink tubes.
2