Chapter 6 Troubleshooting > Error List
175
R
e
v
6.2 Error List
Erro
r
num
ber
Message Cause Corrective action
04 PARAM ROM • Unable to access the
FROM (PARAM ROM) on
the Main PCB.
1. Initialize the parameters.
2. Replace the Main PCB.
104 +35V RECVR • The Power supply (240 W,
36 V) could not be
restored.
1. Replace the Power supply (240 W, 36 V).
2. Replace the Main PCB.
108 HD THERMIS[12] • The Print head
temperature is below -10
°C or greater than 80 °C.
1. Check the cable connection for damage
between the indicated Print head and the Slider
M PCB.
2. Replace the Slider M PCB.
3. Replace the Print head.
108 HD CONNECT[12] • The Print head connection
cannot be confirmed.
108 HD MEM EMP[12] • The head memory is
empty.
10e FROM CLEAR • Unable to clear the FROM
on the Main PCB.
1. Replace the Main PCB.
10f FROM WRITE • Unable to write to the
FROM on the Main PCB.
112 PCB CARTRIG • No Base IO PCB was
detected.
1. Connect then disconnect the FFC between the
Base IO PCB (CN8) and the CART IO PCB
(CN2).
2. Replace the above FFC.
3. Replace the CART IO PCB.
4. Replace the Base IO PCB.
115 PCB MAIN-F1 • Main PCB fuse F1 (+IO5
V) blown.
1. Power on the machine. Check to confirm that
LED29 (F1) illuminates on the Main PCB.
*Check LED illumination before an error
occurs. (The LED will not illuminate if an error
occurs.)
2. If the LED fails to illuminate, check the cable
connection for damage between the Main PCB
(CN9) and the Base IO PCB (CN1).
3. Replace the F1 fuse.
4. If an error occurs while the LED is lit, replace
the Main PCB.
122 CHECK:SDRAM • Unable to recognize
SDRAM on the Main PCB.
1. Update the firmware.
2. Replace the Main PCB.
122 PRAM NONE • Unable to recognize the
DDRII PRAM PCB.
1. Check the DDRII PRAM PCB connection.
2. Replace the DDRII PRAM PCB.
3. Replace the Main PCB.
123 PRAM DATA • PRAM data error.
1. Replace the Main PCB.
124 PRAM ADDR • PRAM address error.
127 POWER OFF • The power does not turn
off after the specified
duration (5 s).
6