EasyManua.ls Logo

MIMAKI TS100-1600 - 3.1.2 Station Height Adjustment

MIMAKI TS100-1600
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 3 Adjustment > Mechanical Adjustment>Station Height Adjustment
110
>
R
e
v
3.1.2 Station Height Adjustment
l Overview
Check to confirm that the station height is within the specified value. If it is not within the specified value,
rotate the height adjustment screw to adjust the gap between the head base (carriage underside) and the
cap cover to the specified value.
l Procedure
1. Select [Maintenance] > [Station Maint.] > [Carriage Out] > [Move To Platen Right End], then press the
[ENTER] key.
2. Turn off the main power supply and unplug the power cable.
3. Lower the clamp lever.
4. Remove the following covers.(1.5)
(1) Front cover upper
(2) Front cover front
(3) Front cover lower right
5. Loosen the two head lock screws.
Note that the head may contact the platen.
6. Set the head height adjustment lever to the "LOW" position.
7. Tighten the two head lock screws.
8. Loosen the four retaining screws.
[Front view]