Chapter 2 Replacement of Maintenance Parts > Sensor Related>Take-up Sensor
51
>
R
e
v
2.2.3 Take-up Sensor
l Procedure
1. Turn off the main power supply and unplug the power cable.
2. Detach the take-up unit cable from the machine.
3. Remove the following covers.(1.5)
(1) Take-up cover
4. Remove the take-up sensor BKT.
5. Disconnect all connectors connected.
6. Remove the Take-up Sensor. (Claw ×4)
7. Follow the procedure in the reverse order for assembly.