Chapter 5 System Overview > Ink System>Initial Filling Sequence
168
>
R
e
v
5.1.5 Initial Filling Sequence
No. Item Overview
1 Fill with the
maintenance liquid.
• Fill the maintenance liquid route.
2 Select the ink type. • Select the ink type.
3 Select the ink set. • Select the ink set.
– Reference: "1.3 Major Parameters"(P. 18)
4 Fill with ink. • Mount the Ink bottle.
– Open all ink valves and fill up to the Head.
– Stop filling if an error occurs.