Chapter 3 Adjustment > Mechanical Adjustment>Jam Sensor Unit Height Adjustment
114
>
R
e
v
3.1.4 Jam Sensor Unit Height Adjustment
l Overview
Check to confirm that the jam sensor unit height is within the specified value. If it is not within the specified
value, adjust so that the gap between the jam sensor unit detecting plate and platen falls within the specified
range.
• [Other required tools]
(1) Thickness gauge (P. 17)
l Procedure
1. Select [Maintenance] > [Station Maint.] > [Carriage Out] > [Move To Platen Right End], then press the
[ENTER] key.
2. Turn off the main power supply and unplug the power cable.
3. Lower the clamp lever.
4. Remove the following covers.(1.5)
(1) Front cover front
(2) Front cover upper
5. Loosen the two head lock screws.
• Note that the head may contact the platen.
6. Set the head height adjustment lever to the "LOW" position.
7. Tighten the two head lock screws.
8. Slightly loosen the jam sensor unit retaining screws.
• Slightly loosen: Unscrew one or two turns.
9. Insert the thickness gauge between the jam sensor unit and the platen.