Chapter 3 Adjustment > Mechanical Adjustment>Jam Sensor Unit Height Adjustment
115
10. Adjust so that the gap between the jam sensor unit detecting plate and platen falls within the specified
range.
Specified value: 2.65 ±0.05 mm
[Front view]
Platen
11. After adjusting, tighten the jam sensor unit retaining screws.
12. Follow the procedure in the reverse order for assembly.