Chapter 3 Adjustment > Adjust Menu>Drop.PosCorrect
128
Reference nozzle row marks: Added in the firmware version 4.4 and later.
7. If adjustment is required, enter the correction value, then press the [ENTER] key.
8. Check the built-in pattern once again.
Repeat the adjustment until no further adjustment is required.
[BiDir] adjustment
Check to confirm that the adjustment nozzle row (ReDir) overlaps the reference nozzle row (SiDir). Adjust if
this is not the case.
l Procedure
1. Position the media.
2. Select [#Adjust] > [Drop.PosCorrect], then press the [ENTER] key.
3. Select the waveform, then press the [ENTER] key.
4. Select the resolution, then press the [ENTER] key.
5. Select the [BiDir], then press the [ENTER] key.
6. Press the [ENTER] key to print the built-in pattern.
Press the key to go to the correction value input screen.
7. Check the built-in pattern.
Check the pattern on the left, right, and center of the print area.
Measure with the magnifying glass scale.
If the lateral offset of the printed area is large, this is probably caused by other factors.
Scandirection
Feeddirection
Less than 30 μm 30 μm or greater
Reference
[OK] [No good]
Reference
nozzle row
marks
Reference nozzle row marks: Added in the firmware version 4.4 and later.
8. If adjustment is required, enter the correction value, then press the [ENTER] key.
9. Check the built-in pattern once again.
Repeat the adjustment until no further adjustment is required.
Reference setting
l Overview
This is an auxiliary adjustment function for expanding (correcting) correction values adjusted using the print
adjustment "720dpi High-Speed" to other resolutions.
Performing Reference setting involves the following processes:
[SiDir] and [ReDir] adjustments: Copy the "720Hi" correction values to other waveforms and each
resolution.
[BiDir] adjustment: Enter the correction values for other waveforms and each resolution.