EasyManua.ls Logo

MIMAKI TS100-1600 - 3.1.1 Carriage Adjustment; Vertical-tilt (slant) adjustment

MIMAKI TS100-1600
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 3 Adjustment > Mechanical Adjustment>Carriage Adjustment
106
>
R
e
v
3.1.1 Carriage Adjustment
l Overview
Check for the carriage vertical-tilt (slant) and sideways slant. If a slant is detected, adjust so that the gap
between the head guard plate and platen falls within the specified range.
[Other required tools]
(1) Thickness gauge (P. 17)
Vertical-tilt (slant) adjustment
l Procedure
1. Select [Maintenance] > [Station Maint.] > [Carriage Out] > [Move To Platen Right End], then press the
[ENTER] key.
2. Turn off the main power supply and unplug the power cable.
3. Lower the clamp lever.
4. Remove the following covers.(1.5)
(1) Front cover front
(2) Front cover upper
(3) Carriage cover
5. Loosen the two head lock screws.
Note that the head may contact the platen.
6. Set the head height adjustment lever to the "LOW" position.
7. Move the carriage slowly.
Move the side panel on the right-hand side of the carriage to the slit line on the platen.
Platen
Carriage side panel
Slit line