Chapter 2 Replacement of Maintenance Parts > Drive Related>Y Driven Pulley
69
>
R
e
v
2.3.6 Y Driven Pulley
l Procedure
1. Select [Maintenance] > [Station Maint.] > [Carriage Out] > [Move To Platen Right End], then press the
[ENTER] key.
2. Turn off the main power supply and unplug the power cable.
3. Remove the following covers.(1.5)
(1) Front cover front
(2) Front cover upper
(3) Left side cover
4. Remove the screws securing the carriage and Y Drive Belt. Pull out the connection to the left-hand side.
5. Loosen the Y-SP plate screw on the left-hand side to relieve the Y Drive Belt tension.
2