Chapter 6 Troubleshooting > Details of Errors and Malfunctions
174
R
e
v
6.1 Details of Errors and Malfunctions
l Overview
This chapter describes troubleshooting procedures for this machine.
You must determine which function(s) the problem involves. Problems can be broadly divided into the
following two categories:
・Have connection conditions (e.g., settings and commands) been
altered?
・Does the problem occur under a specific set of conditions?
・Can the problem be duplicated?
Incorrect handling
Mechanical fault
Hardware fault
Firmware fault
Incorrect RIP setting
Fault with host
Interface cable fault
Machine
Machine
Upload and check parameters.
Reinstall firmware.
Check FFC and cable connections.
Replace or adjust components.
Replace PCB.
Problem persists.
RIP computer
Restart host PC.
Check interface cable connections.
Reinstall RIP software.
Replace computer.
Read the error messages to help determine the cause.
Factory repairs
RIP computer
l Problems involving TS100-1600
• Determined using functions and test function
l Problems involving RIP computer (host)
• Problems involving broken connector cables or faulty contacts
• Problems due to incorrect RIP data settings
• The default machine setting is [Host]. Check the RIP settings.