Chapter 6 Troubleshooting > Error List
176
Erro
r
num
ber
Message Cause Corrective action
128 HDC FIFO OVER • A communication
abnormality was detected
between the Main PCB
and the Slider M PCB.
1. Check the cable connection for damage
between the Main PCB (CN104/CN106) and
the Slider M PCB (CN11).
2. Replace the Slider M PCB.
3. Replace the Main PCB.
4. Replace the Y-drive motor.
5. Retighten the screws on the power supply,
inlet, and other primary components.
6. Check the power supply grounding.
128 HDC FIFO UNDER • A communication
abnormality was detected
between the Main PCB
and the Slider M PCB.
129 BATTERY
EXCHANGE
• The button battery on the
Main PCB is depleted.
1. Replace the CR1220 battery on the Main PCB.
*Replace with an identical or equivalent
battery. Dispose of the used battery as
instructed by the manufacturer.
2. If the problem persists even after replacing the
battery, replace the Main PCB.
12a HDC SPEED • An ink discharge trigger
abnormality was detected.
• A discharge trigger was
detected at a rate
exceeding the discharge
waveform period.
1. Check to confirm the scan parameter is the
default value.
2. Update the firmware.
3. Perform Check Encoder.
4. Check the Linear encoder scale for proper
mounting and for dirt and damage.
5. Replace the Linear encoder scale.
6. Replace the 150LPI Encoder PCB.
7. Replace the Slider M PCB.
12d PCB MAIN-F4 • Main PCB fuse F4 blown
(+IOPOW)
1. Power on the machine. Check to confirm that
D35 (F4) illuminates on the Main PCB.
*Check LED illumination before an error
occurs. (The LED will not illuminate if an error
occurs.)
2. If the LED fails to illuminate, check the cable
connection for damage.
3. Replace the F4 fuse.
4. If an error occurs while the LED is lit, replace
the Main PCB.
130 HD DATA SEQ • A communication
abnormality was detected
between the Main PCB
and the Slider M PCB.
1. Update the firmware.
2. Check the cable connection for damage
between the Main PCB (CN104/CN106) and
the Slider M PCB (CN11).
3. Replace the Main PCB.
4. Replace the Slider M PCB.
5. Replace the Y-drive motor.
148 E-LOG SEQ • A log control abnormality
was detected.
1. Perform [#Test] > [Event Log] to initialize the
event log.
2. Replace the Main PCB.
151 Main PCB V1R2 • An abnormality was
detected in the Main PCB
1.2 V power supply.
1. Check the Power supply (15 W, 5 V) output
voltage (between +4.9 V and +5.3 V).
2. Replace the power supply if the values are
abnormal.
3. Replace the Main PCB.
152 Main PCB V2R5 • An abnormality was
detected in the Main PCB
2.5V power supply.