Chapter 3 Adjustment > Mechanical Adjustment>Adjusting the Path of the Feeding and Take-up Units
123
7. Wind tapes on two wires and mark them.
Feeding unit Take-up unit
8. Remove the wire.
9. Similarly set the wire on the left end, and check to confirm that the marked position on the tape is the
same as the right end.
• Tolerance on the left and right ends: Max. 0.5 mm
• If the difference between left and right ends is 0.5 mm or more, perform the following steps:
(1) Loosen the roll guide screws.
(2) Slide the roll guide to adjust.
(3) After adjusting, tighten the screws.
3