Calibrating the Kaleido-X
Multiviewer Output Calibrations
4 Select the head you wish to calibrate.
5Click the Properties tab.
The audio monitoring delay adjustment control appears. Expand the Calibration
heading to show the control if it is not visible.
6 Select the appropriate unit (milliseconds or AES samples), and then use the slider to
adjust the audio monitoring delay until the audio and video are well synchronized on
the monitor wall display driven by the selected head. Alternatively, type a value
(between 0 and 100 ms, or between 4 and 4800 AES samples) directly in the Audio
monitoring delay box.
7 If appropriate, you may copy the settings from this head to every output head in the
system. To apply the audio monitoring delay calibration globally throughout your
system, click Apply to all.
This has the same effect as selecting every output head one by one, and adjusting the
audio monitoring delay settings to the same values.
Calibrating the Audio Monitoring Color
To calibrate the audio monitoring color
1 In the main window, click the System tab, and then click Description/Calibrations on
the second-level tab bar.
Note: All videos on the monitor wall display controlled by the selected
head are adjusted simultaneously.