132
Calibrating the Kaleido-X
GPI/Genlock Calibrations
5Click Apply to all to apply the chosen value throughout the system.
GPI/Genlock Calibrations
You can define actions that change the state of a GPI output line, and assign them to a
monitor. GPI lines configured as outputs can have their ON/OFF state set manually in XEdit,
for test purposes.
To configure a GPI line’s direction as an output
1 In the main window, click the System tab, and then click Description/Calibrations on
the second-level tab bar.
A hierarchical list representing the current system appears.
2 In the list, expand the multiviewer you wish to calibrate.
3 Expand the GPI/GENLOCK module, and then click the appropriate GPI line element.
4In the Properties tab, click the GPI direction box, and then select output from the list.
5Click Apply to all, if every GPI line in your system is to be configured as an output.
6 To set this GPI output line’s ON/OFF state set manually for test purposes, click the GPI
output box, and then select either ON or OFF from the list.
Notes
• This topic does not apply to the Kaleido-IP.
• GPI direction is pre-defined on the Kaleido-X16 and KMV-3901/3911
multiviewers.