395
Kaleido-X
User’s Manual
From Multiviewer to/from SNMP Devices
From Multiviewer to/from NTP Server
The following ports, used for communications to/from Network Time Protocol servers, are
open by default on all Kaleido-X systems:
Detailed Directions
Assigning an IP Address to Each Device in Your System
Multiviewers and most peripheral devices that are part of a Kaleido-X system communicate
through a TCP/IP network. Configuring your system’s network parameters includes the
following:
Assigning an IP address, and specifying the appropriate network mask, gateway
address, and a system name for each multiviewer. Refer to
Default IP Settings, on
page 382, and to Configuring a Multiviewer’s IP Settings, on page 395.
Configuring the RCP-200, or Kaleido-RCP2, if available. Refer to Configuring the RCP-
200, on page 402, or to Configuring the Kaleido-RCP2, on page 406.
Configuring the Audio Bridge Terminal (ABT), if available. Refer to Configuring an Audio
Bridge Terminal, on page 409.
Configuring a Multiviewer’s IP Settings
To change the Kaleido-X’s system IP address, and adjust your system’s configuration
1 Configure your client PC with an IP address in the same range as the IP address of the
multiviewer (see
Changing the Client PC’s IP Address, on page 400).
2 Open a Web browser window and type the multiviewers IP address in the address
bar.
10
Service Port Transport Notes
SNMP 161 UDP Simple Network Management Protocol, used
for communications between multiviewer
and peripheral devices (e.g. sending get, get-
next, and set commands to an SNMP agent,
and receiving the response).
162 UDP Simple Network Management Protocol, used
for receiving traps (alerts) from peripheral
devices.
Service Port Transport Notes
NTP 123 TCP Used for Network Time Protocol
synchronization. Port needs to be open in
both directions.
10.The multiviewer must have Kaleido-X software version 2.10 or later.