Tally Interface Devices
Zodiak Production Switcher
the Multiviewer). In XEdit’s Channels/Sources tab, configure logical sources using text
sources and system tallies from the Zodiaks serial interface. You will find these elements by
expanding the filtered system list that appears in the Tools pane.
To configure your logical sources
1In the Channels/Sources tab, add the required number of text and alarm levels for your
purposes (see
Creating and Configuring Logical Sources, on page 157).
You may, for example, add one text level to monitor source labels from the Zodiak
switcher, and two alarm levels to monitor Program and Preview tallies.
2 Click a cell that corresponds to the appropriate text level of a logical source.
3 In the filtered System list, navigate to the text element you wish to monitor, and drag it
onto the selected cell.
Zodiak elements available from the filtered system tree, for assignment to text levels in the
Sources table
In the case of the Zodiak outputs (the Preview and Program Outputs you selected, Aux
Output 1 to Aux Output 13, and the Switched Preview Output), from which elements
can be assigned to text levels in your multiviewer’s logical sources, the Kaleido-X
software supports 4 display modes for the labels:
The Zodiak external sources represented in the filtered System list (Input 1 to Input
128), are associated with a single Input label.
Level 1 The label represents the initial background feed.
Level 2 The label represents the initial and the previous
background feed
Level 3 The label represents the previous background feed
Level 4 The label represents the current background feed
(not yet supported)