19 DATA LOGGING FUNCTION
19.3 Procedure for Using
159
19
8. Set the items to be output into the file
*1
, and click [Next].
*1 For details on the setting details, refer to the following table.
Page 175 Data output specifications
9. Set the logging file save destination and file switching
*1
, and click [Next].
*1 For details on the setting details, refer to the following table.
Page 182 Saving and file switching
Setting example 1 Setting example 2
Select the checkbox for "Output data".
Select the checkbox for "Output index".
Select the checkbox for "Output data sampling interval".
Select the checkbox for "Output comments".
Enter Logging Test_Continuation for "Comment".
Select the checkbox for "Output data".
Select the checkbox for "Output trigger information".
Select the checkbox for "Output index".
Select the checkbox for "Output data sampling interval".
Select the checkbox for "Output comments".
Enter Logging Test_Trigger for "Comment".
Setting example 1 Setting example 2
Enter LOG01 for "File save destination".
Select "Simple setting" for "File name".
Enter 3 for "Number of files to be saved".
Select "Overwrite" for "Operation when exceeds the number of files".
Select "Number of records" and enter 1000.
Enter LOG01 for "File save destination".
Select "Simple setting" for "File name".
Enter 3 for "Number of files to be saved".