528
32 TABLE OPERATION
32.2 Operations of Control Method
Operation of the complete flags
The following describes the operation timings of the complete flags. Because dwell time cannot be specified, the flags turn on
immediately after the condition is met.
*1 The flag turns on only for one scan when the drive contact of the instruction turns from OFF to ON.
Item FX3 compatible (Effective only at TBL instruction or
DRVTBL instruction execution)
User specification (Effective only at DRVTBL instruction
or DRVMUL instruction execution)
Instruction execution
complete flag
(SM8029)
Instruction execution
abnormal end flag
(SM8329)
Instruction execution
complete flag
Instruction execution
abnormal end flag
ON
condition
Deceleration stop by pulse
decelerate and stop command
From when the following
operation or function is completed
to when the drive contact is turned
off
The axis is already used.
*1
Shift to the next table is
impossible
Pulse output stop command
Limit of the moving direction
All outputs disabled (SM8034)
Deceleration stop by drive contact
off or pulse decelerate and stop
command
From when the following
operation or function is completed
to when the ON OFF condition
is met
The axis is already used.
Shift to the next table is
impossible
Pulse output stop command
Limit of the moving direction
All outputs disabled (SM8034)
Online change
ON OFF
condition
When the drive contact is turned off The flag remains on until either of the following is performed.
Turning off the flag by the user
Restarting the table instruction
Shift to the next table