Appendix 8 How to Use CPU Module Logging Configuration Tool
871
A
Batch insertion of data
The following window is to insert data items into the data list at once. Data is inserted into blank rows in the list of the "Data"
setting window in order from the top (when a setting already exists in the target insertion row, the row is skipped without
overwriting it).
1. Open the following window.
[Edit] [Batch Data Insertion]
2. Configure the setting items and continuous settings, and click the [OK] button.
Item Description Setting range Default
No. In this column, the data setting numbers from 001 to
128 are displayed.
Device Head Specify the start device number. Page 172 Data to be collected
Last In this column, the end device number calculated
based on the data type and size is displayed.
Data Type Select the type of target data. Page 173 Data type
Size [Byte] Specify the data size when the data type is set to
"String" or "Raw".
1 to 256 bytes
Output Format Clicking the [...] button at the rightmost part of each
row displays the "Output Format (integerfloat)" list.
Select the format to be used when data is output to
the file.
Page 175 Data output
specifications
Item Description Setting range Default
Device Head Same as the data setting (Page 870 Data) Same as the data setting (Page
870 Data)
Last
Data type
Size
Output Format
Continuous
setting
Total number Specify the total number of data items to be inserted
at once.
2 to 128 2
Interval Specify the device interval of data to be inserted at
once.
1 to 262142 1