Document Revision 4C Electra Elite IPK II
2 - 1044 Universal Slots
Refer to the IPK II General Description Manual or System Hardware Manual for more
information.
COI/COID card will show as COI in 10-03-01, but with show correct in 90-34-01.
The following Card Calculator allows you to determine the maximum power consumption
for each cabinet.
The total point value cannot exceed 1000 points for the +5 voltage.
The total point value cannot exceed 1000 points for the -24 voltage.
PVA(X)-U( ) ETU as
CCISoIP
For CCISoIP
Version 1500 or higher – 4-port
license registration provides users with
the flexibility of adding CCISoIP Ports
in increments of four (4, 8, 12, 16, 20
or 24) or (MG 16) DSP Resources in
increments of four (4, 8, 12, and 16).
2 11 Note 4
Note 1: Refer to the KSU Power-Based Calculator Chart.
Note 2: A maximum of three Wireless – DECT BSU(4M)/(2S)/(6S) ETUs can be installed.
Note 3: The IAD(8)-U( ) ETU is assigned as a CCISoIP ETU and counts as eight trunk ports when installed with the IP
CCH ETU application loaded.
Note 4: The PVA(X)-U( ) ETU is assigned as a CCISoIP ETU and counts as 24-trunk ports when installed with the
CCISoIP application package.
Table 2-44 KSU Power-Based Calculator Chart
Package Name
Power Consumption
Number
of ETUs
Equivalent Total
Power Point
+5V -24V +5V -24V
Common
CPUI( )-U( ) ETU 200 0
CF ETU 7 0
EXP-U10 ETU 6 0
MOD-U10 Unit 25 0
Trunk
BRT(4)-U( ) ETU 67 0
COI(4)-U10 ETU 48 5
Table 2-43 Maximum System Capacities for Application Interface ETUs (Continued)
Application
Interface ETUs
Description
Maximum Capacities
Notes
Basic Port
Package
Expanded