Document Revision 4C Electra Elite IPK II
2 - 1112 Warning Tone For Long Conversation
Default Setting
Disabled
Programming
14-01-17 Basic Trunk Data Setup – Trunk to Trunk Warning Tone for Long Conversation Alarm
Enable (1)/Disable (0) whether or not DISA callers should hear the Warning Tone for Long
Conversations.
(default: 0)
14-01-25 Basic Trunk Data Setup – Continued/Discontinued Trunk-to-Trunk Conversation
Enable (1)/Disable (0) whether or not a user should be able to use the continue/discontinued
code.
(default: 0)
20-06-01 Class of Service for Extensions
Assign a Class of Service (1~15) to an extension.
(default: 101 to Class 15 – All others to Class 1)
20-13-01 Class of Service Options (Supplementary Service) – Long Conversation Alarm
Enable (1)/Disable (0) Warning Tone for Long Conversation.
(default: 0)
20-21-01 System Options for Long Conversation – Long Conversation Alarm 1
After a user places a trunk call, the system sends the first warning tone to their extension after
this time (0~64800 seconds).
(default: 170)
20-21-02 System Options for Long Conversation – Long Conversation Alarm 2
After hearing the first warning tone, the system sends additional warning tones after this time
(0~64800 seconds). The warning tones continue, spaced by this interval, until the user hangs
up.
(default: 180)
20-28-01 Trunk to Trunk Conversation – Conversation Continue Code
Enter a single digit Continue Code for the DISA call to use to immediately disconnect or continue
their outside call (0~9,
or # are accepted entries).
(default: No Setting)
20-28-02 Trunk to Trunk Conversation – Conversation Disconnect Code
Enter a single digit Disconnect for the DISA call to use to immediately disconnect or continue
their outside call (0~9,
or # are accepted entries).
(default: No Setting)
20-28-03 Trunk to Trunk Conversation – Conversation Continue Time
When Program 14-01-25 is enabled, determine the time (0~64800 seconds) a call is extended
when the user dials the Continue code (defined in 20-28-01).
(default: 0)